Codes, Incentives & Energy Programs
ThermoDrain is an engineered, third-party certified technology built to maximize building performance, secure lucrative tax credits, and clear modern municipal building code requirements across North America.
Building Codes, Utility Rebates & Energy Modeling Specifications Codes du Bâtiment, Subventions & Modélisation Énergétique ThermoDrain®
Verified compliance pathways and modeling inputs for NRCan HOT2000, CMHC MLI Select, Ontario SB-12, BC Step Code, RESNET HERS (Ekotrope / REM/Rate), MA Stretch Code, and WA WSEC-R. Paramètres officiels pour NRCan HOT2000, SCHL APH Sélect, Ontario SB-12, BC Step Code, Rénoclimat, ainsi que RESNET HERS (Ekotrope / REM/Rate) et WSEC-R.
Canadian Federal & Provincial Code Pathways Programmes Fédéraux & Provinciaux (Canada)
CMHC MLI Select (Post-Sept 30, 2026 Baselines) SCHL APH Sélect (Règles post-30 sept. 2026)
Scored against 2020 NECB Tier 1 (Part 3: ≥25% = 20 pts, ≥50% = 35 pts, ≥60% = 50 pts) and 2020 NBC Tier 1 (Part 9: ≥20% / ≥40% / ≥70%). 4" TD460B risers add +5.5% to +7.8% whole-building savings to unlock 70–100 points and 50-year amortization. Évalué selon le CNÉB 2020 (Partie 3 : ≥25 % = 20 pts, ≥50 % = 35 pts, ≥60 % = 50 pts) et le CNB 2020 (Partie 9 : ≥20 % / ≥40 % / ≥70 %). Les colonnes 4 po TD460B ajoutent +5,5 % à +7,8 % d'économie globale pour débloquer jusqu'à 100 points et un amortissement de 50 ans.
OBC SB-12: Prescriptive vs. Performance Norme SB-12 : Prescriptif vs Performance
Prescriptive path (Article 3.1.1.12) mandates ≥ 42.0% CSA B55.1 (TDX3350 at 42.10%). Under Performance / HOT2000 (Subsection 3.1.2), TDX3615 (55.04%) and TDX3720 (57.20%) generate +1.65 to +1.92 GJ/yr above the 42.0% Reference House to offset >22% glazing or avoid triple-pane upgrades. La voie prescriptive (art. 3.1.1.12) exige ≥ 42,0 % CSA B55.1 (TDX3350 à 42,10 %). En voie de performance HOT2000 (sous-section 3.1.2), les modèles TDX3615 (55,04 %) et TDX3720 (57,20 %) génèrent +1,65 à +1,92 GJ/an au-dessus de la maison de référence (42,0 %) pour compenser un vitrage > 22 %.
BC Energy Step Code & Zero Carbon EL-4 BC Energy Step Code & Zero Carbon
The BC Step Code Reference House includes 0% baseline DWHR—100% of ThermoDrain's 6.3–7.8 GJ/yr recovery counts toward Step 3 (20% better) and Step 4 (40% better), while preventing 4.5 kW resistance backup draw on EL-4 Heat Pump Water Heaters. La maison de référence BC Step Code ne comporte aucun RCEG : 100 % des 6,3 à 7,8 GJ/an comptent vers les Niveaux 3 (20 %) et 4 (40 %), tout en empêchant l'enclenchement de l'élément d'appoint de 4,5 kW des chauffe-eau thermopompes (EL-4).
Rénoclimat, Novoclimat & Efficiency Manitoba Rénoclimat, Novoclimat & Efficiency Manitoba
Québec: Rénoclimat provides $120–$180 for new DWHR installs; Novoclimat and Hydro-Québec require ≥ 42.0% CSA B55.1. Manitoba: In Zone 7A (5.5°C mains), TDX3615/TDX3720 delivers +10.2% to +10.6% whole-house gain toward $2,000–$15,000 New Homes rebates. Québec : Rénoclimat accorde 120 $ à 180 $ pour l'ajout d'un RCEG; Novoclimat et Hydro-Québec exigent ≥ 42,0 % CSA B55.1. Manitoba : En Zone 7A (eau à 5,5 °C), un TDX3615/TDX3720 procure +10,2 % à +10,6 % d'amélioration vers les rabais New Homes (2 000 $ à 15 000 $).
NRCan HOT2000 & CAN-QUEST Engineering Modeling Inputs Paramètres de modélisation NRCan HOT2000 & CAN-QUEST
| Modeling Parameter Paramètre | TDX3240 (3") | TDX3350 (3") | TDX3615 (3") | TDX3720 (3") | TD460B (4" MURB) |
|---|---|---|---|---|---|
| Nominal Height Hauteur nominale | 24.0" (610 mm) | 35.0" (889 mm) | 61.5" (1,562 mm) | 72.0" (1,829 mm) | 60.0" (1,524 mm) |
| CSA B55.1 Efficiency (9.5 L/min) Rendement CSA B55.1 (9,5 L/min) | 33.59% | 42.10% (SB-12 Min) | 55.04% | 57.20% | 57.30% |
| Potable Pressure Drop (9.5 L/min) Perte de charge potable (9,5 L/min) | < 1.8 psi | ≤ 2.2 psi | ≤ 2.5 psi | 1.9 psi | 2.2 psi (Intertek) |
| HOT2000 Annual Savings (Equal Flow) Économie annuelle HOT2000 (Débit égal) | 4.2–4.9 GJ/yr | 5.3–6.1 GJ/yr | 6.9–8.0 GJ/yr | 7.2–8.3 GJ/yr | ~2.1 GJ/suite/yr |