CODES DU BÂTIMENT THERMODRAIN

Chez EcoInnovation Technologies, nous suivons et respectons les lignes directrices du code du bâtiment établies par chaque province.

US Regulatory & Statutory Compliance • National, State & Municipal Codes

US Building, Energy & Plumbing Code Compliance Guide.

This technical compliance brief provides Authorities Having Jurisdiction (AHJs), municipal building and plumbing inspectors, HERS raters, and mechanical specifying engineers (PE) with the statutory code references, testing accreditations, and installation criteria governing ThermoDrain® Drain-Water Heat Recovery (DWHR) systems across the United States.

Download MasterFormat 22 31 16 Submittal Specs View Official Third-Party Tested Ratings → Code Verification Inquiry
IECC / IRC
Sections R403.5.4, C404.7 & N1103.5.4
IPC & UPC
Vented Double-Wall Separation (Sec. 608)
ANSI / RESNET 301
HERS Index Calculation & Modeling Standard
Sec. 45L / 179D
Federal IRA Energy Tax Deduction Compliance
Statutory Model Codes

International Energy Conservation Code (IECC) & IRC Requirements

In the United States model codes, Drain-Water Heat Recovery units are regulated under explicit statutory mandates that cite CSA B55.1 and CSA B55.2 as the national reference consensus standards:

IECC Section R403.5.4 & IRC Section N1103.5.4 — Drain Water Heat Recovery Units: Model Code Mandate

"Drain water heat recovery units shall comply with CSA B55.2. Drain water heat recovery units shall be tested in accordance with CSA B55.1. Potable water-side pressure loss of drain water heat recovery units shall be less than 3 psi (20.7 kPa) for individual units connected to one or two showers. Potable water-side pressure loss of drain water heat recovery units shall be less than 2 psi (13.8 kPa) for individual units connected to three or more showers."

Commercial Mandate (IECC Section C404.7): Requires CSA B55.2 compliance, testing to CSA B55.1, and maximum potable pressure loss < 10 psi (69 kPa) at peak commercial design flow.

CSA B55.1 Testing & Pressure Verification

ThermoDrain® thermal efficiency ratings and potable-side pressure curves are independently tested and certified in strict accordance with CSA B55.1.

  • Residential units exhibit certified potable head loss ≤ 2.5 psi at rated 2.5 gpm flow, exceeding the 3 psi model code threshold.
  • Performance ratings are indexed in public directories, providing AHJs with immediate verification for plan approval.

IPC Section 608 Double-Wall Potable Protection

Under International Plumbing Code (IPC) Section 608.17.2, heat exchangers using potable water to absorb heat from non-potable wastewater must feature double-wall isolation.

  • ThermoDrain is engineered with an unpressurized, atmospheric capillary relief gap (CSA B55.2).
  • In the event of a mechanical failure, fluid drips visibly to the floor; greywater cannot enter the drinking water supply under any operating or siphon condition.
State Regulations

State-Level Energy Code Implementation & Point Packages

Key state-level amendments provide substantial prescriptive credits and performance compliance options for DWHR installations:

Washington State (WSEC-R) Option 5.1

Under WSEC-R Table 406.3 (Energy Credits), DWHR is designated under Option 5.1. Installing a CSA B55.1 tested DWHR unit (minimum 42% efficiency, such as the ThermoDrain TDX3350) connected to primary shower drains earns 0.5 to 1.5 prescriptive energy credits, significantly lowering envelope construction costs.

California Title 24 (Part 6) Sec. 150.1 / 170.2

Recognized as a high-value water heating compliance option for Single-Family (Section 150.1(c)8) and Multi-Family buildings (Section 170.2(d)3). Requires testing to CSA B55.1 / B55.2 and field inspection via HERS Rater Field Verification (Reference Appendix RA3.6.9) to verify pipe diameter, slope, and water heater preheat alignment.

New York State (NYStretch) Energy Code

Under the NYStretch Energy Code and 2020 ECCC NYS, DWHR serves as an approved Service Water Heating (SWH) efficiency measure. It reduces modeled source Energy Use Intensity (EUI), allowing builders to satisfy multi-family ERI and performance stretch targets.

Oregon (ORSC Table 1101.1) Measure D

The Oregon Residential Specialty Code includes DWHR in the Additional Measure Selection Table. Specifying a unit with ≥ 40% efficiency satisfying CSA B55.1 fulfills the mandatory residential water heating energy efficiency measure.

Statutory Harmonization

US Plumbing & Mechanical Code Summary Matrix

Cross-reference of national model codes, testing benchmarks, and potable connection rules:

Code / Standard Statutory Section Efficiency Baseline Permitted Piping Routing
IECC (Residential) Section R403.5.4 Tested to CSA B55.1 Water heater preheat, or dual-feed (equal flow). Pressure loss < 3 psi (1–2 showers) or < 2 psi (3+ showers).
IECC (Commercial) Section C404.7 CSA B55.1 tested efficiency Preheat to commercial boiler makeup or storage tanks exclusively. Pressure loss < 10 psi at peak design flow.
IRC (One- & Two-Family) Section N1103.5.4 Tested to CSA B55.1 Water heater preheat, or dual-feed. Double-wall per CSA B55.2 required.
IPC (Plumbing Code) Section 608.17.2 CSA B55.2 double-wall safety Vented double-wall isolation required between wastewater and potable supply lines.
California Title 24 Part 6 (150.1(c)8 & 170.2(d)3) CSA B55.1 / CEC Listed Water heater preheat or equal flow. Mandatory HERS verification (RA3.6.9).
Washington State (WSEC) Table 406.3 (Option 5.1) ≥ 42% (CSA B55.1) Water heater preheat or equal flow. Earns 0.5 to 1.5 Energy Credits.
Energy Modeling & Federal Incentives

ANSI/RESNET 301, HERS Scores & IRA Section 45L / 179D

Under ANSI/RESNET/ICC Standard 301, DWHR is modeled in the Domestic Hot Water (DHW) calculation algorithms, directly reducing the Energy Rating Index (ERI) score:

HERS Index Reduction (2 to 5 Points)

Energy modelers utilizing Ekotrope, REM/Rate, or EnergyGauge can directly select the ThermoDrain model and certified CSA B55.1 efficiency:

  • Routinely achieves a 2- to 5-point drop in total HERS score at low capital expenditure.
  • Provides the compliance margin required to satisfy ENERGY STAR for New Homes Version 3.1 / 3.2 and DOE Zero Energy Ready Home (ZERH) program targets.

IRA Section 45L & Section 179D Tax Deductions

Directly unlocks major federal tax incentives under the Inflation Reduction Act (IRA):

  • Section 45L ($2,500 to $5,000 per dwelling unit): Lowers modeled HERS EUI to satisfy DOE ZERH and ENERGY STAR certification thresholds in multi-family and single-family developments.
  • Section 179D (up to $5.00+ per sq. ft.): Accelerates commercial building deductions by reducing source building energy and power costs relative to ASHRAE 90.1 baselines.
Electrification & Grid Reliability: Heat Pump Water Heater (HPWH) Morning Peak Shaving Peer-Reviewed Analysis

As state energy codes mandate all-electric construction, electric utilities face a severe coincident morning peak (6:00 AM–8:30 AM). In cold winter climates, a single shower demands over 17 kW of instantaneous thermal load, quickly depleting storage capacity and forcing 4,500W electric backup resistance elements to engage simultaneously across thousands of homes. Passive DWHR reduces instantaneous shower demand by 30% to 50%, preserving tank temperature stratification and keeping HPWHs in high-efficiency compressor mode without backup element snapback.

On-Site Field Verification

Plumbing Inspector & HERS Rater Field Rough-In Checklist

Standard field verification points for municipal AHJs, plumbing inspectors, and third-party HERS raters:

1. Vertical Alignment & Plumb (±5°)

The unit must be mounted vertically on the DWV stack within 5 degrees of true plumb. Annular falling-film heat transfer requires gravity to maintain uniform fluid contact along the entire interior copper wall.

2. Shielded Mechanical Couplings

TD4 & Commercial Series: Must be connected to cast iron, PVC, or ABS stacks using heavy-duty, shielded stainless-steel mechanical couplings conforming to ASTM C1277 or CISPI 310 (e.g., Fernco Proflex, Husky HD). Non-shielded rubber slip-couplings are prohibited.

3. Counterflow Piping Orientation

Incoming cold supply water must enter the bottom port and exit through the top port. This establishes the certified counterflow thermal gradient against falling drain effluent.

4. Vented Double-Wall Air Gap Clearance

Verify that the atmospheric leak path around the coil manifold is fully open to ambient air. The capillary vent gap must not be covered with insulation, spray foam, or construction tape.

Energy Modeler Specification

Software Entry Guidelines (Ekotrope, REM/Rate, EnergyPlus)

Input certified CSA B55.1 ratings directly into approved energy simulation engines:

  1. In the Service Hot Water (DHW) equipment tab, enable Drain Water Heat Recovery (DWHR).
  2. Select system piping configuration: "Preheat to Water Heater Only" or "Equal Flow" (Dual-Feed) based on field plumbing rough-in.
  3. Specify the percentage of home showers plumbed through the unit (typically 100% when all upper/main baths route to the central stack).
  4. Enter the official CSA B55.1 certified efficiency from the verified registry:
    • TDX3240B (24" core): 33.59%
    • TDX3350 (35" core - Meets WSEC 42% threshold): 42.10%
    • TDX3615 (61.5" core - High Efficiency / Net Zero): 55.04%
    • TD442 (4" × 42" commercial riser): 46.20%
    • TD460 (4" × 60" commercial riser): 55.30%
    • TD472 (4" × 72" commercial riser): 59.10%